$474.37 Reg.
$397.95 SALE
|
Item Number FLK337A
|
|
Quantity:
|
|
A new, ergonomic concept, shaped
to fit your hand and to access tight spots easily. The
series feature a large display with backlight so readings
can be taken in virtually any lighting situation.
Auto-shut-off maximizes battery life so the meter works when
you need it.
|
Features: |
- Small body and jaws fit perfectly in your hand and
into tight places
- Measures MIN/MAX capability
- Precise measurements with 2.0% basic accuracy
- True-RMS measurements
- Measures AC current to 999.9 A
- Measures DC current to 999.9 A
- Measures AC volts to 600 V
- Measures DC volts to 600 V
- Resistance measurement to 600.0 Ω
- Continuity for quick checking of shorts
- Handy 'Display Hold' button keeps measurements on
the display
- Meter controls are positioned so current
measurements can be done
with one hand (index finger on clamp opening lever and
thumb on
rotary switch)
- In-rush current function:measures starting current
for motors, lighting, etc.
- Auto shut-off maximizes battery life; Automatic low
battery indicator
- Improved low current measurement accuracy from new
microprocessor technology
|
337A
Clamp Meter includes: |
- Fluke 337A Digital Clamp Meter
- Coated instruction card
- Safety information sheet
- Soft carrying case
- TL75 test leads
- Two AA Alkaline batteries
|
|
Voltage DC |
Range: 0 - 600 V
Accuracy: 1% ± 5 counts
|
Voltage AC |
Range: 0 - 600 V
Accuracy: 1% ± 5 counts (50 /60 Hz), 6% ± 5
counts (100-400 Hz)
AC Response: True-rms
|
Current DC |
Range:
0 – 999.9 A
Accuracy: 2% ± 5 counts (50 - 60 Hz) |
Current AC |
Range: 0 – 999.9 A
Accuracy: 2% ± 5 counts (10-100 Hz), 6% ± 5
counts (100 - 400 Hz)
Crest Factor (50/60 Hz):
3 @ 500A, 2.5 @ 600A, 1.42@1000 A, add 2% for CF>2
AC Response: True-rms
|
Resistance |
Range:
0 - 600.0 Ω, 6001 - 6000 Ω
Accuracy: 1.5% ± 5 counts |
Continuity |
<=
30 Ω |
Inrush Current
|
Integration
Time: 100 ms
|
Environmental Specifications:
|
Operating
Temperature |
-10ºC to 50ºC, -14ºF
to 122ºF
|
Storage Temperature |
-30ºC to 60ºC, -22ºF
to 140ºF |
Operating Altitude |
2,500 meters max,
6,500 ft max |
Temperature De-Rating
|
Add 0.1 x specified
accuracy for each ºC above 28ºC or
below 18ºC (above 82.4°F or below 64.4°F) |
Safety Specifications:
|
Safety |
IEC 1010-2-032, 600V
CAT III
|
Mechanical & General Specifications:
|
Size |
250mm x
80mm x 40mm (9.875" x 3.125" x 1.625") |
Weight |
310 g |
Warranty |
Three years |
Battery Life |
Alkaline approx. 150
hrs continuous Automatic low battery indicator |
Display Hold |
Yes |
|
|